Strona 1 - Programming Guide

Omnidirecional Laser ScannerProgramming GuideESPECIFIC ACIONES SUJE TAS A C AMBIO SIN PRE VIO A VISO .

Strona 2

2 ADVANCED PROGRAMMING GUIDE 2. CHANGE THE SCANNER SETTING In order to change the scanner setting, please follow the steps below: 1. Scan the

Strona 3

92 ADVANCED PROGRAMMING GUIDE 2. Emulation Data Output Selection The decoded data output logic level can be set to befit the external decoder. Wand

Strona 4 - Radio Notice

93 ADVANCED PROGRAMMING GUIDE Wand Data Transmitted as Scanning Enable Wand output data format as Code 39

Strona 5

94 ADVANCED PROGRAMMING GUIDE 3. Emulation data idle state selection The level refer to wand emulation data signal when not in use Idle=high

Strona 6

95 ADVANCED PROGRAMMING GUIDE Data Editing

Strona 7

96 ADVANCED PROGRAMMING GUIDE HEADER AND TRAILER The Header and Trailer allows you to append a header and/or a trailer to every message transmitted

Strona 8

97 ADVANCED PROGRAMMING GUIDE Trailer (Postamble) Save setting to confirm

Strona 9

98 ADVANCED PROGRAMMING GUIDE Truncate Header/Trailer Character This setting allows you to truncate a number of header or trailer for symbology.

Strona 10 - ADVANCED PROGRAMMING GUIDE

99 ADVANCED PROGRAMMING GUIDE Truncate header character Truncate trailer character

Strona 11

100 ADVANCED PROGRAMMING GUIDE Add Code Length This option allows you to add the reading barcode numeric characters as header Add code length as h

Strona 12

101 ADVANCED PROGRAMMING GUIDE Symbology Configuration In this section, device can be programmed to recognize one or more barcode symbologi

Strona 13

3 ADVANCED PROGRAMMING GUIDE Default Values of Keyboard Emulation Parameters Function Default Values Keyboard type selection IBM PC/AT USA Message

Strona 14

102 ADVANCED PROGRAMMING GUIDE Reading code selection Code 39 enable Code 39 disable

Strona 15

103 ADVANCED PROGRAMMING GUIDE Codabar enable Codabar disable

Strona 16

104 ADVANCED PROGRAMMING GUIDE UPC/EAN/JAN enable UPC/EAN/JAN disable (only can’t transmitted but can decode)

Strona 17

105 ADVANCED PROGRAMMING GUIDE ITF 2 of 5 enable ITF 2 of 5 disable

Strona 18

106 ADVANCED PROGRAMMING GUIDE Chinese postcode enable Chinese postcode disable

Strona 19

107 ADVANCED PROGRAMMING GUIDE Code 128 enable Code 128 disable

Strona 20 - Sleep Timeouts Selection

108 ADVANCED PROGRAMMING GUIDE Code 93 enable Code 93 disable

Strona 21

109 ADVANCED PROGRAMMING GUIDE EAN-128 enable EAN-128 disable

Strona 22

110 ADVANCED PROGRAMMING GUIDE EAN convert to ISSN/ISBN EAN convert to ISSN/ISBN disable

Strona 23

111 ADVANCED PROGRAMMING GUIDE Code 32 enable Code 32 disable

Strona 24

4 ADVANCED PROGRAMMING GUIDE Default Values of Decoding Parameters Function Code Default Value Code 39 Enable ITF 2 of 5 Disable Chinese Post C

Strona 25

112 ADVANCED PROGRAMMING GUIDE MSI enable MSI disable

Strona 26

113 ADVANCED PROGRAMMING GUIDE UPC/EAN Parameters setting In this section, device can be programmed to recognize some or all derivatives of UPC/EAN

Strona 27

114 ADVANCED PROGRAMMING GUIDE EAN-8 or EAN-13 enable UPC-A and EAN-13 Enable

Strona 28 - Same Code Delay Time

115 ADVANCED PROGRAMMING GUIDE UPC-A and UPC-E Enable UPC-A enable

Strona 29

116 ADVANCED PROGRAMMING GUIDE UPC-E enable EAN-13 enable

Strona 30

117 ADVANCED PROGRAMMING GUIDE EAN-8 enable

Strona 31

118 ADVANCED PROGRAMMING GUIDE 2. Force UPC-E to UPC-A format Force UPC-E to UPC-A format enable Force UPC-E to UPC-A format

Strona 32

119 ADVANCED PROGRAMMING GUIDE 3. Force UPC-A to EAN-13 format Force UPC-A to EAN-13 format enable Force UPC-A to EAN-13 form

Strona 33

120 ADVANCED PROGRAMMING GUIDE 4. Force EAN-8 to EAN-13 format Force EAN-8 to EAN-13 format disable Force EAN-8 to EAN-13 fo

Strona 34

121 ADVANCED PROGRAMMING GUIDE EAN-13 first “0” can transmitted EAN-13 first “0” can’t transmitted

Strona 35

5 ADVANCED PROGRAMMING GUIDE PROGRAM PROCEDURE USING BARCODE MENUS Read Enter/Exit programming mode barcode to start of configu

Strona 36

122 ADVANCED PROGRAMMING GUIDE 5. Transmit UPC-A check digit Transmit UPC-A check digit enable Transmit UPC-A check digit di

Strona 37

123 ADVANCED PROGRAMMING GUIDE 6. Transmit UPC-E leading character Transmit UPC-E leading character enable Transmit UPC-E l

Strona 38

124 ADVANCED PROGRAMMING GUIDE 7. Transmit UPC-E check digit Transmit UPC-E check digit enable Transmit UPC-E check digit d

Strona 39

125 ADVANCED PROGRAMMING GUIDE 8. Transmit EAN-8 check digit Transmit EAN-8 check digit enable Transmit EAN-8 check digit d

Strona 40

126 ADVANCED PROGRAMMING GUIDE 9. Transmit EAN-13 check digit Transmit EAN-13 check digit enable Transmit EAN-13 check digi

Strona 41

127 ADVANCED PROGRAMMING GUIDE 10. Transmit UPC-A leading character Transmit UPC-A leading character enable Transmit UPC-a l

Strona 42

128 ADVANCED PROGRAMMING GUIDE 11. Addendum UPC/EAN add on off Add on 5 only

Strona 43

129 ADVANCED PROGRAMMING GUIDE Add on 2 only Add on 2 or 5

Strona 44

130 ADVANCED PROGRAMMING GUIDE 12. Add on format Add on format with separator Add on format without separator

Strona 45

131 ADVANCED PROGRAMMING GUIDE EAN/UPC +Add on (none mandatory) EAN/UPC + Add on(mandatory)

Strona 46 - Code Setting

6 ADVANCED PROGRAMMING GUIDE System Setting The series scanner is a multi-interface communication scanner. If you had ordered

Strona 47

132 ADVANCED PROGRAMMING GUIDE EAN/UPC + add on mandatory for 378/379 French Supplement requirement not sent for other EAN/UPC

Strona 48

133 ADVANCED PROGRAMMING GUIDE EAN/UPC + addon mandatory for 434/439 German Supplement requirement Not sent for other EAN/UPC

Strona 49

134 ADVANCED PROGRAMMING GUIDE EAN/UPC + add on mandatory for 378/379 French Supplement requirement optionally for other EAN/

Strona 50

135 ADVANCED PROGRAMMING GUIDE EAN/UPC + add on mandatory for 434/439 German Supplement requirement optionally for other EAN/U

Strona 51

136 ADVANCED PROGRAMMING GUIDE EAN/UPC + add on mandatory for 491 Japanese (bookland) Supplement requirement optionally for other

Strona 52

137 ADVANCED PROGRAMMING GUIDE Double code not allowed Double code mandatory for 978/192

Strona 53

138 ADVANCED PROGRAMMING GUIDE Double code format without separator Double code format with separator

Strona 54

139 ADVANCED PROGRAMMING GUIDE Double code format with free (one character)

Strona 55

140 ADVANCED PROGRAMMING GUIDE 13. Data Redundant Check In this section, user can set decoder data redundant check, before it is accepted as a good

Strona 56

141 ADVANCED PROGRAMMING GUIDE UPC-A data redundant check = 2 UPC-A data redundant check = 3

Strona 57

7 ADVANCED PROGRAMMING GUIDE Reset (Return of factory default) Reading of “Reset” barcode label turns all parameters back to default values, and the

Strona 58 - Character delay

142 ADVANCED PROGRAMMING GUIDE UPC-E Data Redundant Check UPC-E data redundant check = 0 UPC-E data redundant check = 1

Strona 59

143 ADVANCED PROGRAMMING GUIDE UPC-E data redundant check = 2 UPC-E data redundant check = 3

Strona 60

144 ADVANCED PROGRAMMING GUIDE EAN-13 Data Redundant Check EAN-13 data redundant check = 0 EAN- 13 data redundant check = 1

Strona 61

145 ADVANCED PROGRAMMING GUIDE EAN-13 data redundant check = 2 EAN-13 data redundant check = 3

Strona 62

146 ADVANCED PROGRAMMING GUIDE EAN-8 Data Redundant Check EAN-8 data redundant check = 0 EAN-8 data redundant check = 1

Strona 63

147 ADVANCED PROGRAMMING GUIDE EAN-8 data redundant check =2 EAN-8 data redundant check = 3

Strona 64

148 ADVANCED PROGRAMMING GUIDE 2 digit addendum data redundant check 2 digit addendum data redundant check = 0 2 digit addendu

Strona 65

149 ADVANCED PROGRAMMING GUIDE 2 digit addendum data redundant check = 2 2 digit addendum data redundant check = 3

Strona 66

150 ADVANCED PROGRAMMING GUIDE 5 digit addendum data redundant check 5 digit addendum data redundant check = 0 5 digit adden

Strona 67

151 ADVANCED PROGRAMMING GUIDE 5 digit addendum data redundant check =2 5 digit addendum data redundant check = 3

Strona 68

8 ADVANCED PROGRAMMING GUIDE Abort (Exit programming mode) Reading of the “Abort” barcode label discards all the parameters read prior to scan the “

Strona 69

152 ADVANCED PROGRAMMING GUIDE Addendum seek timeout Addendum seek timeout =6 Addendum seek timeout=7

Strona 70

153 ADVANCED PROGRAMMING GUIDE Addendum seek timeout=8 Addendum seek timeout=9

Strona 71

154 ADVANCED PROGRAMMING GUIDE Addendum seek timeout=10

Strona 72

155 ADVANCED PROGRAMMING GUIDE Code 39 parameters setting The scanner can program to support the standard code 39 or Full ASCII code 39. In addit

Strona 73

156 ADVANCED PROGRAMMING GUIDE Start/Stop Character Transmission Code 39 start/stop character transmission Code 39 start/stop

Strona 74

157 ADVANCED PROGRAMMING GUIDE Check Digit Code 39 check digit calculate and transmit Code 39 check digit calculate but withou

Strona 75

158 ADVANCED PROGRAMMING GUIDE No check character

Strona 76

159 ADVANCED PROGRAMMING GUIDE 1. Code 39 reading length setting The default code 39 length is 3 ~32 character. It can be set at minimum 1 digit a

Strona 77

160 ADVANCED PROGRAMMING GUIDE Code 39 minimum length setting Save setting to confirm

Strona 78

161 ADVANCED PROGRAMMING GUIDE Concatenation Code 39 concatenation enable Code 39 concatenation disable

Strona 79

9 ADVANCED PROGRAMMING GUIDE Return to RS-232 default The RS-232C interface scanner is often used when connecting to the serial port of a PC or term

Strona 80

162 ADVANCED PROGRAMMING GUIDE Code 32 “A” Character Transmit Code 32 (Italian pharmacy) transmit “A” character Code 32(Italia

Strona 81

163 ADVANCED PROGRAMMING GUIDE 2. Data Redundant Check In this section, users can use labels to set decoder data redundant check, before it is acce

Strona 82

164 ADVANCED PROGRAMMING GUIDE Code 39 data redundant check = 2 Code 39 data redundant check = 3

Strona 83

165 ADVANCED PROGRAMMING GUIDE CODABAR Parameters Setting In this section, there are varies settings for Codabar symbology, including: • Check c

Strona 84

166 ADVANCED PROGRAMMING GUIDE Codabar start/stop character transmission ---- DC1~DC4 Codabar start/stop character transmiss

Strona 85

167 ADVANCED PROGRAMMING GUIDE 2. CODABAR reading length setting The default CODABAR length is 6 ~32 character. It can be set at minimum 1 digit a

Strona 86

168 ADVANCED PROGRAMMING GUIDE Codabar minimum length setting Save setting to confirm

Strona 87

169 ADVANCED PROGRAMMING GUIDE 3. Concatenation Codabar concatenation disable Codabar concatenation enable

Strona 88

170 ADVANCED PROGRAMMING GUIDE 4. Check digit No check character Check digits calculate but not transmit

Strona 89

171 ADVANCED PROGRAMMING GUIDE Check digit calculate and transmit

Strona 90

10 ADVANCED PROGRAMMING GUIDE Return to wand emulation default The Wand emulation is achieved by decoding a scanned barcode and then encoding it aga

Strona 91

172 ADVANCED PROGRAMMING GUIDE 5. Data Redundant Check In this section, users can set decoder data redundant check, before it is accepted as a good

Strona 92

173 ADVANCED PROGRAMMING GUIDE Codabar data redundant check = 2 Codabar data redundant check = 3

Strona 93

174 ADVANCED PROGRAMMING GUIDE Code 128 Parameters Setting In this section, there are varies setting for Code 128 symbology, including: • Check

Strona 94

175 ADVANCED PROGRAMMING GUIDE Calculate but not transmit Calculate and transmit

Strona 95 - USB interface configuration

176 ADVANCED PROGRAMMING GUIDE 2. Code 128 FNC2 concatenation This function permits the temporary storage of a code in the decoder, if this code s

Strona 96

177 ADVANCED PROGRAMMING GUIDE 3. Code 128 reading length setting The default code 128 length is 3 ~62 character. It can be set at minimum 1 di

Strona 97

178 ADVANCED PROGRAMMING GUIDE Code 128 minimum length setting Save setting to confirm

Strona 98 - Wand emulation configuration

179 ADVANCED PROGRAMMING GUIDE 4. EAN-128 FNC1 CHARACTER EAN-128 FNC1 Character transmitted EAN-128 FNC1 not character transm

Strona 99

180 ADVANCED PROGRAMMING GUIDE 5. Data Redundant Check In this section, users can set decoder data redundant check, before it is accepted as a good

Strona 100

181 ADVANCED PROGRAMMING GUIDE Code 128 data redundant check = 2 Code 128 data redundant check = 3

Strona 101

11 ADVANCED PROGRAMMING GUIDE Save as customer default Reading of this label to save the desired parameters set into customer’s own default setting.

Strona 102

182 ADVANCED PROGRAMMING GUIDE ITF 2 of 5 Parameters Setting In this section, there are varies ITF 2 of 5 symbology including: • Check character

Strona 103 - Data Editing

183 ADVANCED PROGRAMMING GUIDE ITF 2 of 5 check digit calculate and transmit ITF 2 of 5 check digit calculate but without

Strona 104 - HEADER AND TRAILER

184 ADVANCED PROGRAMMING GUIDE 2. ITF 2 of 5 reading length setting The default ITF 2 of 5 length is 6 ~32 character. It can be set at minimum 2 d

Strona 105

185 ADVANCED PROGRAMMING GUIDE ITF 2 of 5 code minimum length setting Save setting to confirm

Strona 106

186 ADVANCED PROGRAMMING GUIDE ITF 2 of 5 one fixed length setting ITF 2 of 5 two fixed length setting

Strona 107

187 ADVANCED PROGRAMMING GUIDE 3. Data Redundant Check In this section, users can set decoder data redundant check, before it is accepted as a good

Strona 108

188 ADVANCED PROGRAMMING GUIDE ITF 25 data redundant check = 2 ITF 25 data redundant check = 3

Strona 109 - Symbology Configuration

189 ADVANCED PROGRAMMING GUIDE Chinese post code parameters setting In this section, there are varies Chinese post code symbology including: • D

Strona 110

190 ADVANCED PROGRAMMING GUIDE Chinese post code minimum length setting Save setting to confirm

Strona 111

191 ADVANCED PROGRAMMING GUIDE 2. Data Redundant Check The option allows you to set decoder data redundant check, before it is accepted as a good

Strona 112

Enter/Exit Programming Mode (This barcode is also found at back cover page.) Framed values are default values.

Strona 113

12 ADVANCED PROGRAMMING GUIDE Sleep Timeouts Selection In the section, user can set both laser and/or motor to enter into sleep

Strona 114

192 ADVANCED PROGRAMMING GUIDE Chinese post code data redundant check = 2 Chinese post code data redundant check = 3

Strona 115

193 ADVANCED PROGRAMMING GUIDE MSI/PLESSY code Parameters Setting In this section, there are varies set up for Chinese post code symbology, includin

Strona 116

194 ADVANCED PROGRAMMING GUIDE MSI/PLESSY double check digit calculate but only first digit transmit MSI/PLESSY double check d

Strona 117

195 ADVANCED PROGRAMMING GUIDE 2. Single Check Digit MSI/PLESSY single check digit calculate but without transmit MSI/Plessy

Strona 118

196 ADVANCED PROGRAMMING GUIDE 3. MSI/PLESSY code reading length setting The default MSI/PLESSY code length is 6~32 character. It can be set at mi

Strona 119

197 ADVANCED PROGRAMMING GUIDE MSI/PLESSY minimum length setting Save setting to confirm

Strona 120

198 ADVANCED PROGRAMMING GUIDE 4. Data Redundant Check The option allows you to set decoder data redundant check, before it is accepted as a good r

Strona 121

199 ADVANCED PROGRAMMING GUIDE MSI data redundant check = 2 MSI data redundant check = 3

Strona 122

200 ADVANCED PROGRAMMING GUIDE Code 93 Parameters Setting In this section, there are varies set up for Code 93 symbology, including: • Check cha

Strona 123

201 ADVANCED PROGRAMMING GUIDE Code 93 check digit not calculate and without transmit Code 93 check digit calculate and transm

Strona 124

13 ADVANCED PROGRAMMING GUIDE Motor sleep mode off Motor sleep time 5 min.

Strona 125

202 ADVANCED PROGRAMMING GUIDE 2. Code 93 code reading length setting The default Code 93 code length is 3 ~32 character. It can be set at minimum

Strona 126

203 ADVANCED PROGRAMMING GUIDE Code 93 minimum length setting Save setting to confirm

Strona 127

204 ADVANCED PROGRAMMING GUIDE 3. Data Redundant Check The option allows you to set decoder data redundant check before it is accepted as a good re

Strona 128

205 ADVANCED PROGRAMMING GUIDE Code 93 data redundant check = 2 Code 93 data redundant check = 3

Strona 129

206 ADVANCED PROGRAMMING GUIDE Full ASCII Code Table

Strona 130

207 ADVANCED PROGRAMMING GUIDE Full ASCII --- NUL Full ASCII ---- SOH (Function Key---Ins)

Strona 131

208 ADVANCED PROGRAMMING GUIDE Full ASCII ----STX (Function Key---Del) Full ASCII ---- ETX (Function Key---Home)

Strona 132

209 ADVANCED PROGRAMMING GUIDE Full ASCII ---- EOT (Function Key---End) Full ASCII ---- ENQ (Function Key---Up arrow)

Strona 133

210 ADVANCED PROGRAMMING GUIDE Full ASCII ---- ACK (Function Key---Down arrow) Full ASCII ---- BEL (Function Key---Left arrow)

Strona 134

211 ADVANCED PROGRAMMING GUIDE Full ASCII ---- BS (Function Key---Backspace) Full ASCII ---- HT (Function Key---Tab)

Strona 135

14 ADVANCED PROGRAMMING GUIDE Motor sleep time 10 min. Motor sleep time 20 min.

Strona 136

212 ADVANCED PROGRAMMING GUIDE Full ASCII ---- LF (Function Key---Enter(num)) Full ASCII ---- VT (Function Key---Right arrow)

Strona 137

213 ADVANCED PROGRAMMING GUIDE Full ASCII ---- FF (Function Key---PgUp) Full ASCII ---- CR (Function Key---Enter(alphabet))

Strona 138

214 ADVANCED PROGRAMMING GUIDE Full ASCII ---- SO (Function Key---PgDn) Full ASCII ---- SI (Function Key---Shift)

Strona 139

215 ADVANCED PROGRAMMING GUIDE Full ASCII ---- DLE (Function Key---5(num)) Full ASCII ---- DC1 (Function Key---F1)

Strona 140

216 ADVANCED PROGRAMMING GUIDE Full ASCII ---- DC2 (Function Key---F2) Full ASCII ---- DC3 (Function Key---F3)

Strona 141

217 ADVANCED PROGRAMMING GUIDE Full ASCII ---- DC4 (Function Key---F4) Full ASCII ---- NAK (Function Key---F5)

Strona 142

218 ADVANCED PROGRAMMING GUIDE Full ASCII ---- SYN (Function Key---F6) Full ASCII ---- ETB (Function Key---F7)

Strona 143

219 ADVANCED PROGRAMMING GUIDE Full ASCII ---- CAN (Function Key---F8) Full ASCII ---- EN (Function Key---F9)

Strona 144

220 ADVANCED PROGRAMMING GUIDE Full ASCII ---- SUB (Function Key---F10) Full ASCII ---- ESC (Function Key---F11)

Strona 145

221 ADVANCED PROGRAMMING GUIDE Full ASCII ---- FS (Function Key---F12) Full ASCII ---- GS (Function Key---ESC)

Strona 146

15 ADVANCED PROGRAMMING GUIDE Motor sleep time 30 min. Motor sleep time 60 min.

Strona 147

222 ADVANCED PROGRAMMING GUIDE Full ASCII ---- RS (Function Key---Ctl(L)) Full ASCII ---- US (Function Key---Alt(L))

Strona 148 - 13. Data Redundant Check

223 ADVANCED PROGRAMMING GUIDE Full ASCII ---- SP Full ASCII ---- !

Strona 149

224 ADVANCED PROGRAMMING GUIDE Full ASCII ---- “ Full ASCII ---- #

Strona 150

225 ADVANCED PROGRAMMING GUIDE Full ASCII ---- $ Full ASCII ---- %

Strona 151

226 ADVANCED PROGRAMMING GUIDE Full ASCII ---- & Full ASCII ---- ‘

Strona 152

227 ADVANCED PROGRAMMING GUIDE Full ASCII ---- ( Full ASCII ---- )

Strona 153

228 ADVANCED PROGRAMMING GUIDE Full ASCII ---- * Full ASCII ---- +

Strona 154

229 ADVANCED PROGRAMMING GUIDE Full ASCII ---- , Full ASCII ---- -

Strona 155

230 ADVANCED PROGRAMMING GUIDE Full ASCII ---- . Full ASCII ---- /

Strona 156

231 ADVANCED PROGRAMMING GUIDE Full ASCII ---- 0 Full ASCII ---- 1

Strona 157

16 ADVANCED PROGRAMMING GUIDE Laser sleep mode off Laser sleep time 5 min.

Strona 158

232 ADVANCED PROGRAMMING GUIDE Full ASCII ---- 2 Full ASCII ---- 3

Strona 159

233 ADVANCED PROGRAMMING GUIDE Full ASCII ---- 4 Full ASCII ---- 5

Strona 160

234 ADVANCED PROGRAMMING GUIDE Full ASCII ---- 6 Full ASCII ---- 7

Strona 161

235 ADVANCED PROGRAMMING GUIDE Full ASCII ---- 8 Full ASCII ----9

Strona 162

236 ADVANCED PROGRAMMING GUIDE Full ASCII ---- : Full ASCII ---- ;

Strona 163 - Code 39 parameters setting

237 ADVANCED PROGRAMMING GUIDE Full ASCII ---- < Full ASCII ---- =

Strona 164

238 ADVANCED PROGRAMMING GUIDE Full ASCII ---- > Full ASCII ---- ?

Strona 165

239 ADVANCED PROGRAMMING GUIDE Full ASCII ---- @ Full ASCII ---- A

Strona 166 - No check character

240 ADVANCED PROGRAMMING GUIDE Full ASCII ---- B Full ASCII ---- C

Strona 167

241 ADVANCED PROGRAMMING GUIDE Full ASCII ---- D Full ASCII ---- E

Strona 168

17 ADVANCED PROGRAMMING GUIDE Laser sleep time 10 min. Laser sleep time 15 min.

Strona 169

242 ADVANCED PROGRAMMING GUIDE Full ASCII ---- F Full ASCII ---- G

Strona 170

243 ADVANCED PROGRAMMING GUIDE Full ASCII ---- H Full ASCII ---- I

Strona 171

244 ADVANCED PROGRAMMING GUIDE Full ASCII ---- J Full ASCII ---- K

Strona 172

245 ADVANCED PROGRAMMING GUIDE Full ASCII ---- L Full ASCII ---- M

Strona 173

246 ADVANCED PROGRAMMING GUIDE Full ASCII ---- N Full ASCII ---- O

Strona 174

247 ADVANCED PROGRAMMING GUIDE Full ASCII ---- P Full ASCII ---- Q

Strona 175

248 ADVANCED PROGRAMMING GUIDE Full ASCII ---- R Full ASCII ---- S

Strona 176

249 ADVANCED PROGRAMMING GUIDE Full ASCII ---- T Full ASCII ---- U

Strona 177

250 ADVANCED PROGRAMMING GUIDE Full ASCII ---- V Full ASCII ---- W

Strona 178

251 ADVANCED PROGRAMMING GUIDE Full ASCII ---- X Full ASCII ---- Y

Strona 179

18 ADVANCED PROGRAMMING GUIDE Laser sleep time 20 min. Laser sleep time 25 min.

Strona 180

252 ADVANCED PROGRAMMING GUIDE Full ASCII ---- Z Full ASCII ---- [

Strona 181

253 ADVANCED PROGRAMMING GUIDE Full ASCII ---- \ Full ASCII ---- ]

Strona 182

254 ADVANCED PROGRAMMING GUIDE Full ASCII ---- ^ Full ASCII ---- _

Strona 183

255 ADVANCED PROGRAMMING GUIDE Full ASCII ---- ` Full ASCII ---- a

Strona 184

256 ADVANCED PROGRAMMING GUIDE Full ASCII ---- b Full ASCII ---- c

Strona 185

257 ADVANCED PROGRAMMING GUIDE Full ASCII ---- d Full ASCII ---- e

Strona 186

258 ADVANCED PROGRAMMING GUIDE Full ASCII ---- f Full ASCII ---- g

Strona 187

259 ADVANCED PROGRAMMING GUIDE Full ASCII ---- h Full ASCII ---- i

Strona 188

260 ADVANCED PROGRAMMING GUIDE Full ASCII ---- j Full ASCII ---- k

Strona 189

261 ADVANCED PROGRAMMING GUIDE Full ASCII ---- l Full ASCII ---- m

Strona 190

19 ADVANCED PROGRAMMING GUIDE Laser sleep time 30 min.

Strona 191

262 ADVANCED PROGRAMMING GUIDE Full ASCII ---- n Full ASCII ---- o

Strona 192

263 ADVANCED PROGRAMMING GUIDE Full ASCII ---- p Full ASCII ---- q

Strona 193

264 ADVANCED PROGRAMMING GUIDE Full ASCII ---- r Full ASCII ---- s

Strona 194

265 ADVANCED PROGRAMMING GUIDE Full ASCII ---- t Full ASCII ---- u

Strona 195

266 ADVANCED PROGRAMMING GUIDE Full ASCII ---- v Full ASCII ---- w

Strona 196

267 ADVANCED PROGRAMMING GUIDE Full ASCII ---- x Full ASCII ---- y

Strona 197

268 ADVANCED PROGRAMMING GUIDE Full ASCII ---- z Full ASCII ---- {

Strona 198

269 ADVANCED PROGRAMMING GUIDE Full ASCII ---- | Full ASCII ---- }

Strona 199

270 ADVANCED PROGRAMMING GUIDE Full ASCII ---- ~ Full ASCII ---- DEL

Strona 200

271 ADVANCED PROGRAMMING GUIDE APPENDIXES

Strona 201

20 ADVANCED PROGRAMMING GUIDE Same Code Delay Time This parameter sets the minimum time allowed between decodes of the same l

Strona 202

272 ADVANCED PROGRAMMING GUIDE APPENDIX A CODE 39 FULL ASCII CODE TABLE ASCII CODE 39 VALEUR HEXA. ASCII CODE 39 VALEUR HEXA.NUL %U 00 % /E

Strona 203

273 ADVANCED PROGRAMMING GUIDE APPENDIX A CODE 39 FULL ASCII CODE TABLE ASCII CODE 39 VALEUR HEXA. ASCII CODE 39 VALEUR HEXA.J J 4A e +E 65

Strona 204

274 ADVANCED PROGRAMMING GUIDE APPENDIX B FUNCTION KEY EMULATION FUNCTION KEY ASCII CODE 39 FUNCTION KEY ASCII CODE 39 Ins $A 01 F1 $Q 11 Del

Strona 205

275 ADVANCED PROGRAMMING GUIDE Enter/Exit programming

Strona 206

21 ADVANCED PROGRAMMING GUIDE Same code delay time 50 msec. Same code delay time 100 msec.

Strona 207

IMPORTANT NOTICE No warranty of any kind is made in regard to this material, including, but not limited to, implied warranties of merchantability or

Strona 208 - Code 93 Parameters Setting

22 ADVANCED PROGRAMMING GUIDE Same code delay time 200 msec. Same code delay time 300 msec.

Strona 209

23 ADVANCED PROGRAMMING GUIDE Same code delay time 400 msec. Same code delay time 500 msec.

Strona 210

24 ADVANCED PROGRAMMING GUIDE Same code delay time 600 msec. Same code delay time 700 msec.

Strona 211

25 ADVANCED PROGRAMMING GUIDE Same code delay time 800 msec. Same code delay time 900 msec.

Strona 212

26 ADVANCED PROGRAMMING GUIDE Same code delay time 1000 msec. Same code delay time infinite

Strona 213

27 ADVANCED PROGRAMMING GUIDE Beeper Sound Selection This section includes all setting labels for beeper sound, settings inclu

Strona 214 - Full ASCII Code Table

28 ADVANCED PROGRAMMING GUIDE Led/Beep after transmission Led/Beep before transmission

Strona 215

29 ADVANCED PROGRAMMING GUIDE Power-up tone enable Power-up tone disable

Strona 216

30 ADVANCED PROGRAMMING GUIDE Sleep sound Sleep silent

Strona 217

31 ADVANCED PROGRAMMING GUIDE Medium beeper tone Low beeper tone

Strona 218

Radio Notice Some equipment generates uses and can radiate radio frequency energy. If not installed and used in accordance with the instructions in

Strona 219

32 ADVANCED PROGRAMMING GUIDE High beeper tone Speaker disable

Strona 220

33 ADVANCED PROGRAMMING GUIDE Beeper sound duration (100msec) Beeper sound duration (50msec)

Strona 221

34 ADVANCED PROGRAMMING GUIDE Beeper sound duration (20msec) Beeper sound duration (5msec)

Strona 222

35 ADVANCED PROGRAMMING GUIDE Beeper sound duration 200msec Beeper sound duration 500msec

Strona 223

36 ADVANCED PROGRAMMING GUIDE Loud beeper volume Medium beeper volume

Strona 224

37 ADVANCED PROGRAMMING GUIDE Low beeper volume

Strona 225

38 ADVANCED PROGRAMMING GUIDE Barcode Identifier Code Setting The scanner can transmit maximum 2 digits barcode identifier co

Strona 226

39 ADVANCED PROGRAMMING GUIDE Barcode Identifier Code Selection Disable identifier code Scan “Enable identifier code” label to transmit th

Strona 227

40 ADVANCED PROGRAMMING GUIDE Set Message Format with Code Identifier IS02 Code Code identifier UPC-A A UPC-E E EAN-8 FF EAN-13 F CODE 39 * CODB

Strona 228

41 ADVANCED PROGRAMMING GUIDE Barcode Identifier Code Setting Code 39 identifier code setting ITF 2 of 5 identifier code setti

Strona 229

Laser Safety The laser scanner complies with safety standard IEC 60825-1 for a Class I laser produce. It also complies with CDRH as applicable to a

Strona 230

42 ADVANCED PROGRAMMING GUIDE Chinese Post code identifier code setting UPC-E identifier code setting

Strona 231

43 ADVANCED PROGRAMMING GUIDE UPC-A identifier code setting EAN-13 identifier code setting

Strona 232

44 ADVANCED PROGRAMMING GUIDE EAN-8 identifier code setting Codabar identifier code setting

Strona 233

45 ADVANCED PROGRAMMING GUIDE Code 128 identifier code setting Code 93 identifier code setting

Strona 234

46 ADVANCED PROGRAMMING GUIDE MSI identifier code setting Save setting to confirm

Strona 235

47 ADVANCED PROGRAMMING GUIDE Message delay In this section contains different delay time frame between two consecutive messag

Strona 236

48 ADVANCED PROGRAMMING GUIDE Inter message delay 0 ms Inter message delay 100 ms

Strona 237

49 ADVANCED PROGRAMMING GUIDE Inter message delay 500 ms Inter message delay 1000 ms

Strona 238

50 ADVANCED PROGRAMMING GUIDE Character delay This option governs delay time between two consecutive characters; the delay time

Strona 239

51 ADVANCED PROGRAMMING GUIDE Character delay 5 ms Inter character delay 0 ms

Strona 240

TABLE OF CONTENTS Introduction... 1 Changing the sc

Strona 241

52 ADVANCED PROGRAMMING GUIDE Inter character delay 10 ms Inter character delay 20 ms

Strona 242

53 ADVANCED PROGRAMMING GUIDE Inter character delay 50 ms

Strona 243

54 ADVANCED PROGRAMMING GUIDE Interface Communication Setting This section contains labels to configure the scanner to user’s host t

Strona 244

55 ADVANCED PROGRAMMING GUIDE RS-232C interface configuration 1. Baud Rate setting Baud Rate 38400 Baud Rate 19200

Strona 245

56 ADVANCED PROGRAMMING GUIDE Baud Rate 9600 Baud Rate 4800

Strona 246

57 ADVANCED PROGRAMMING GUIDE Baud Rate 2400 Baud Rate 1200

Strona 247

58 ADVANCED PROGRAMMING GUIDE Baud Rate 57600 Baud Rate 115200

Strona 248

59 ADVANCED PROGRAMMING GUIDE 2. Date Bit Setting 7 data bit 8 data bit

Strona 249

60 ADVANCED PROGRAMMING GUIDE 3. Stop Bit Setting 1 Stop bit 2 Stop bit

Strona 250

61 ADVANCED PROGRAMMING GUIDE 4. Parity Bit Setting Even Parity Odd Parity

Strona 251

USB interface configuration... 87 Keyboard type ...

Strona 252

62 ADVANCED PROGRAMMING GUIDE Mark Parity Space Parity

Strona 253

63 ADVANCED PROGRAMMING GUIDE None Parity

Strona 254

64 ADVANCED PROGRAMMING GUIDE 5. Handshaking Protocol The RS-232C type scanner supports four handshaking protocols. With these options of communica

Strona 255

65 ADVANCED PROGRAMMING GUIDE None handshaking ACK/NAK

Strona 256

66 ADVANCED PROGRAMMING GUIDE Xon/Xoff RTS/CTS

Strona 257

67 ADVANCED PROGRAMMING GUIDE 6. ACK/NAK Response Time Setting ACK/NAK response time 300ms ACK/NAK response time 500ms

Strona 258

68 ADVANCED PROGRAMMING GUIDE ACK/NAK response time 1s ACK/NAK response time 2s

Strona 259

69 ADVANCED PROGRAMMING GUIDE ACK/NAK response time 3s ACK/NAK response time 5s

Strona 260

70 ADVANCED PROGRAMMING GUIDE ACK/NAK response time Infinity Disable ACK/NAK timeout beeper

Strona 261

71 ADVANCED PROGRAMMING GUIDE Enable ACK/NAK timeout beeper Enable beeper on<BEL> character

Strona 262

Chinese postcode parameters setting ... 189 Chinese postcode reading length setting ...

Strona 263

72 ADVANCED PROGRAMMING GUIDE Ignore beep on <BEL>character

Strona 264

73 ADVANCED PROGRAMMING GUIDE 7. Message terminator for RS-232C The series RS-232C type scanner can be programmed to append a terminator to every m

Strona 265

74 ADVANCED PROGRAMMING GUIDE RS-232 message terminator-CR RS-232 message terminator-LF

Strona 266

75 ADVANCED PROGRAMMING GUIDE RS-232 message terminator-H tab RS-232 message terminator-STX/ETX

Strona 267

76 ADVANCED PROGRAMMING GUIDE RS-232 message terminator-EOT

Strona 268

77 ADVANCED PROGRAMMING GUIDE Keyboard wedge interface configuration 1. Message terminator for keyboard Wedge Keyboard terminator---none

Strona 269

78 ADVANCED PROGRAMMING GUIDE Keyboard terminator---H-TAB

Strona 270

79 ADVANCED PROGRAMMING GUIDE 2. Keyboard Language Selection Enable International keyboard type (Alt method) Keyboard language

Strona 271

80 ADVANCED PROGRAMMING GUIDE Keyboard language support---Germany Keyboard language support---UK

Strona 272

81 ADVANCED PROGRAMMING GUIDE Keyboard language support---French Keyboard language support---Spanish

Strona 273

1 ADVANCED PROGRAMMING GUIDE 1. INTRODUCTION This is a advanced programming guide for varies omnidirectional laser scanners, this guide contains a

Strona 274

82 ADVANCED PROGRAMMING GUIDE Keyboard language support--- Italian Keyboard language support--- Swiss

Strona 275

83 ADVANCED PROGRAMMING GUIDE Keyboard language support---Swedish Keyboard language support---Japanese

Strona 276

84 ADVANCED PROGRAMMING GUIDE Keyboard language support---Belgium

Strona 277

85 ADVANCED PROGRAMMING GUIDE 3. Capital Lock Select the suitable code to match your keyboard caps lock status Capital lock on C

Strona 278

86 ADVANCED PROGRAMMING GUIDE 4. Function Key Emulation In this section, user can emulate Function keys, Arrow keys, and many other “extended” keys.

Strona 279 - APPENDIXES

87 ADVANCED PROGRAMMING GUIDE USB interface configuration The USB mode is effectively a keyboard emulator that works with hosts, such as USB-compa

Strona 280 - APPENDIX A

88 ADVANCED PROGRAMMING GUIDE 2. Message terminator for USB None Enter

Strona 281

89 ADVANCED PROGRAMMING GUIDE H tab

Strona 282

90 ADVANCED PROGRAMMING GUIDE Wand emulation configuration 1. Emulation Speed Selection The data output speed can be set to befit the external deco

Strona 283

91 ADVANCED PROGRAMMING GUIDE Wand emulation speed= high (300 us narrow element width) Wand emulation speed ---- higher (100us

Komentarze do niniejszej Instrukcji